FEATURES
Can be used with either Rotary or Touch-Tone service
Memory retention during power failure (EEPROM)
Crystal decoder guarantees correct touch-tone decoding
Toll restrictor
Front panel or remote programming
Tamper-resistant programming security
Aluminum construction resists vandalism
Instant remote system checking
Selectable 1 - 9 minute talk time
Secondary relay standard for controlling a secondary device
Flush and Surface Models Available
Modular Construction allows use in almost any size building
NO-PHONE-LINE (OPTION) FEATURES
No monthly line rental or message unit fees.
Provides intercom for tenants that do not have outside telephone line service
Distinctive double ring differentiates between visitor calls and incoming calls
Connection for guard or concierge phone
Multiple entrance capability
Only two wires to interface with lobby equipment
Built-in call-waiting feature
DOC and FCC approved
SPECIFICATIONS
| Dimensions: | Height: |
19.00" (483mm)
|
| | Width: |
Depends upon number of modules wide. (See frame/housing chart # IL312).
|
| | Depth: |
4.00" (102mm) (Flush Housings)
|
| | Projects: |
2.25" (58mm) (Surface Mount Frames--not including handset).
0.88" (22mm) (Flush Mount Frames--not including handset).
|
| Construction: |
Anodized extruded aluminum panel/faceplate.
|
| Housings: |
OH190 series, for flush style OF190 frames only.
|
ARCHITECTS' AND ENGINEERS' SPECIFICATIONS
Telephone Entry system shall be Alpha Communications®/Tektone® TE905A Tek-Entry III
series or approved equal. The system shall operate on standard dedicated telephone lines,
unless the No-Phone-Line options are used. All TE905A units shall include integral power supply,
panel-mounted PC board, metal telephone touch pad, busy and door-open indication, postal
release option, and armored cord handset with a special hook switch, or speaker/microphone
panel module. The TE905A system shall allow for 1 to 1,000 apartment capacity.
The TE905A system shall provide a relay output for controlling door, gate, elevator, etc., and shall
be able to dial out on either rotary or touch-tone service. It shall also provide built-in capability for
multiple entrances, and it shall be possible to program the system remotely, or at the unit itself.
Construction shall be of extruded, anodized aluminum, modular style panels.
Contractor shall provide the proper number of AM190D alphabetical directory modules, depending
upon the number of apartments served. Directory modules shall be protected by a clear sheet of
polycarbonate plastic. The panels shall be provided with the appropriate OF190 (Flush) or
OF190S (Surface) panel frame. Flush panels shall be supplied with the appropriate (OH190
series) flush back box. Contractor shall provide a model S1 screwdriver, to the building management,
for any future directory name replacement or maintenance required.
-----ADD FOR NO-PHONE-LINE OPTION-----
For No-Phone-Line service capability, contractor shall include all of the required components of a
standard TE905A system, plus a PM900 No-Phone-Line controller, one or more IH996 relay board
cabinets, RY912 relay boards and the CT912 relay board connector assemblies. All equipment
shall be located in the telephone equipment room, adjacent to the RJ71C jacks, installed by the
local phone company.
REQUIRED COMPONENTS:
|
S1
|
Screwdriver (for installation/maintenance).
|
|
TE905A
|
Master Control Module for 1 to 1,000 remote stations. Includes speaker/microphone.
|
|
SS106
|
transformer for power and minimum 2-gang panel frame.
|
|
OF190S
|
Series Surface Panel Frame. Available up to 11 modules.
|
| ------OR------ |
|
OF190
|
Series Flush Panel Frame. Available up to 11 modules
|
| -----AND----- |
|
OH190
|
Series Flush Housing--not required for surface panels.
|
|
SS106
|
16VAC transformer. One (1) required to power the TE905A and one (1) required to
power the 16VAC electric door opener (if used). One (1) additional SS106 is required
when using the PM900 "No-Phone-Line" optional controller. One (1) additional SS106
is required when using the PK124 battery charge, for battery back-up capabilities.
|
OPTIONAL COMPONENTS:
|
PK124
|
Battery Charger. One (1) required if system battery back-up is required. Requires
SS106 transformer for power and two (2) BA001 batteries.
|
|
BA001
|
12VDC Battery. Two (2) required when using the PK124 battery charger unit.
|
|
TA900
|
Privacy handset module. Used on TE905A panels when open-voice is not wanted. Adds
one (1) module (in width) to panel size. The TA900 is a factory-wired option only and
cannot be installed in the field. It must be ordered at the same time as the master.
|
OPTIONAL "No-Phone Line" COMPONENTS:
|
PM900
|
No-Phone-Line Control Unit. One (1) required per system, for No-Phone-Line option.
Requires one (1)SS106 transformer for power.
|
|
IH996
|
Relay Board Cabinet (surface mount). Each IH996 can hold up to (8) RY912 relay
boards.
|
|
RY912
|
No-Phone-Line Relay Board. One (1) required for each 12 remote apartment stations.
Each RY912 requires a CT912 connector assembly.
|
|
CT912
|
Connector Assembly. One (1) required for each RY912 relay board.
|
|
WT2833NL
|
"Dummy Telephone". Used on No-Phone-Line systems to allow tenants who do not
have outside phone lines to answer the lobby intercom call, and release the electric
door opener. Plugs into existing apartment phone jack. Has built-in flashing red neon
lamp, for the hearing-impaired.
NOTE: The "No-Phone-Line" option requires that the contractor have the local phone company
install one (1) RJ71C type interface jack, for each 12 (or less) remote apartment stations.
|
|