FEATURES
Can be used with either Rotary or Touch-Tone service
Memory retention during power failure (EEPROM)
Crystal decoder guarantees correct touch-tone decoding
Programmable system master code
Night service feature will redirect all calls to guard/concierge station
Tamper-resistant programming security
Vandal-Resistant Painted Steel Construction
Multiple entrance capability (add only additional lobby entry panels)
Door timer cut-off
Fire alarm input for emergency door release
Modular Construction allows use in almost any size building
Panel access protected by built-in keyed lock
NO-PHONE-LINE (OPTION) FEATURES
No monthly line rental or message unit fees.
Provides intercom for tenants that do not have outside telephone line service
Distinctive double ring differentiates between visitor calls and incoming calls
Connection for guard or concierge phone
Multiple entrance capability
Only two wires to interface with lobby equipment
Built-in call-waiting feature
DOC and FCC approved
SPECIFICATIONS/DIMENSIONS
| TE903A | Height: |
16.00" (406mm)
|
| | Width: |
11.00" (279mm)
|
| | Projects: |
2.65" (67mm) (From finished wall surface--not including optional handset).
|
| TE904 | Height: |
13.00" (330mm)
|
| | Width: |
19.00" (483mm)
|
| | Projects: |
2.75" (70mm) (From finished wall surface--not including optional handset).
|
| AM903D | Height: |
16.00" (406mm)
|
| | Width: |
11.00" (279mm)
|
| | Projects: |
2.65" (67mm) (From finished wall surface).
|
| Construction: |
16 gauge painted steel front panel.
|
| Housings: |
None required. Fully surface mount construction.
|
ARCHITECTS' AND ENGINEERS' SPECIFICATIONS
Telephone Entry system shall be Alpha Communications®/Tektone® TE903A/TE904 Tek-Entry
III series or approved equal. The system shall operate on standard dedicated telephone lines
(unless the No-Phone-Line) options are used. All TE903A/TE904 units shall a zinc die-cast
marine quality metal telephone keypad, postal release option, and speaker/microphone (or
optional handset). The TE903A/TE904 system shall allow for 1 to 1,000 apartment capacity.
The TE903A/TE904 system shall provide a relay output for controlling door, gate, elevator, etc.,
and shall be able to dial out on either rotary or touch-tone service. It shall also provide built-in
capability for multiple entrances, and it shall be possible to program the system right at the
master unit itself.
Construction shall be of 16 gauge (painted) steel built into a weather-resistant hooded housing.
Contractor shall provide the proper number of AM903D alphabetical directory add on modules,
depending upon the number of apartments served. Directory modules shall be protected by a
clear sheet of polycarbonate plastic.
-----ADD FOR NO-PHONE-LINE OPTION-----
For No-Phone-Line service capability, contractor shall include all of the required components of a
standard TE903A/TE904 system, plus a PM900 No-Phone-Line controller, one or more IH996
relay board cabinets, RY912 relay boards and the CT925 relay board connector assemblies. All
equipment shall be located in the telephone equipment room, adjacent to the RJ71C jacks,
installed by the local phone company.
REQUIRED COMPONENTS:
|
TE903A
|
Master Control Module for 1 to 1,000 remote stations. Includes speaker/microphone,
and built-in 100-name directory module. Requires SS106 transformer for power.
|
| ------OR------ |
|
TE904
|
Master Control Module for 1 to 1,000 remote stations. Includes speaker/microphone,
and built-in 200-name directory module. Requires SS106 transformer for power.
|
|
AM903D
|
200-Name Capacity Alphabetical Directories (for TE903 master units).
|
|
SS106
|
16VAC transformer. One (1) required to power the TE903 (or TE904) and one (1)
required to power the 16VAC electric door opener (if used). One (1) additional SS106 is
required when using the PM900 "No-Phone-Line" optional controller. One (1) additional
SS106 is required when using the PK124 battery charge, for battery back-up
capabilities.
|
OPTIONAL COMPONENTS:
|
PK124
|
Battery Charger. One (1) required if system battery back-up is required. Requires
SS106 transformer for power and two (2) BA001 batteries.
|
|
BA001
|
12VDC Battery. Two (2) required when using the PK124 battery charger unit.
|
|
TA902
|
Privacy handset module. Used on TE903A or TE904 masters when open-voice is not
wanted. NOTE: Must be ordered at same time as the master station. The TA902 is a
factory-wired option only and cannot be installed in the field.
|
OPTIONAL "No-Phone Line" COMPONENTS:
|
PM900
|
No-Phone-Line Control Unit. One (1) required per system, for No-Phone-Line option.
Requires one (1) SS106 transformer for power.
|
|
IH996
|
Relay Board Cabinet (surface mount). Each IH996 can hold up to (8) RY912 relay
boards.
|
|
RY912
|
No-Phone-Line Relay Board. One (1) required for each 12 remote apartment stations.
Each RY912 requires a CT925 connector assembly.
|
|
CT925
|
Connector Assembly. One (1) required for each RY912 relay board.
|
|
WT2833NL
|
"Dummy Telephone". Used on No-Phone-Line systems to allow tenants who do not
have outside phone lines to answer the lobby intercom call, and release the electric
door opener. Plugs into existing apartment phone jack. Has built-in flashing red neon
lamp, for the hearing-impaired.
NOTE: The "No-Phone-Line" option requires that the contractor have the local phone company
install one (1) RJ71C type interface jack, for each 12 (or less) remote apartment stations.
|
WIRING REQUIREMENTS:
See TE903A/TE904 system wiring diagram and system programming manual for more complete
wiring information.
|