FEATURES
Built-in Amplifier in Each Master Station
Powers from Low-Cost 24VAC Transformer
Built-in Electronic Call Tone Signal or Electronic Buzzer (selectable)
Built-in Electric Door Release Pushbutton on all Masters
Modern Styling
Masters can be Surface or Desk Mounted (with appropriate housings)
Wide Variety of Weather-Resistant Remotes
Built-in Multi-Color L.E.D. Call-in Indicator and Busy Lights
Privacy Switch
Dip Switch Selectable Features
Optional All-Call and/or Music Capability
SPECIFICATIONS/DIMENSIONS
| SM401: | Height: |
7.00" (178mm)
|
| | Width: |
5.00" (127mm)
|
| | Projects: |
3.38" (86mm) from surface of wall when surface mounted using IH400A
|
| IR100B: | Height: |
7.00" (178mm)
|
| | Width: |
5.00" (127mm)
|
| | Depth: |
0.63" (17mm) when flush mounted
|
| IR141P: | Height: |
7.00" (178mm)
|
| | Width: |
5.00" (127mm)
|
| | Depth: |
0.63" (17mm) when flush mounted
|
| IR143P: | Height: |
7.00" (178mm)
|
| | Width: |
5.00" (127mm)
|
| | Depth: |
0.63" (17mm) when flush mounted
|
| IR141U: | Height: |
7.00" (178mm)
|
| | Width: |
5.00" (127mm)
|
| | Depth: |
0.63" (17mm) when flush mounted
|
| IR510B: | Height: |
7.00" (178mm)
|
| | Width: |
5.00" (127mm)
|
| | Depth: |
0.63" (17mm) when flush mounted
|
| OR610: | Height: |
5.25" (134mm)
|
| | Width: |
4.00" (102mm)
|
| | Projects: |
1.25" (32mm) from surface of wall
|
| OR642: | Height: |
5.25" (134mm)
|
| | Width: |
4.00" (102mm)
|
| | Projects: |
1.25" (32mm) from surface of wall
|
| OR510: | Height: |
7.00" (178mm)
|
| | Width: |
5.00" (127mm)
|
| | Depth: |
0.63" (17mm) when flush mounted
|
| OR502SS: | Height: |
7.00" (178mm)
|
| | Width: |
5.00" (127mm)
|
| | Depth: |
0.63" (17mm) when flush mounted
|
| OR541U: | Height: |
7.00" (178mm)
|
| | Width: |
5.00" (127mm)
|
| | Depth: |
0.63" (17mm) when flush mounted
|
| IH400A: | Height: |
2.00" (51mm) from desk surface
|
| | Width: |
5.00" (127mm)
|
| | Depth: |
7.00" (178mm)
|
| IH700W: | Height: |
7.00" (178mm)
|
| | Width: |
5.00" (127mm)
|
| | Depth: |
1.75" (45mm) from surface of wall
|
| OH700: | Height: |
7.00" (178mm)
|
| | Width: |
5.00" (127mm)
|
| | Depth: |
1.75" (45mm) from surface of wall
|
| PK400: | Height: |
5.50" (140mm)
|
| | Width: |
5.00" (80mm)
|
| | Depth: |
2.00" (51mm) from surface of wall
|
ARCHITECTS' AND ENGINEERS' SPECIFICATIONS
The intercom system shall be Alpha Communications®/Tektone Tek-Select II series, or approved
equal. Master stations shall be model SM401 (or SM404 or SM406 or SM411) and shall be
surface mount (or desk mount) and shall include a built-in voice amplifier, electronic tone signal,
multi-color L.E.D.S, Busy light indicators, selectable function DIP switches, Privacy and Call
Switches, Talk/Listen Switch, slide type volume control, momentary electric door release push-
button, and All-Call switch. System shall be powered by the PK400 power supply, which is
powered by a 24VAC transformer (model SS106). Outdoor remote station shall be the model
OR642 (or model OR603W or model _______). Indoor remote shall be model IR510B (or model
IR100B) with appropriate backbox/ housing. Remote station(s) (other than the IR100B) shall have
built-in momentary call pushbutton and shall be constructed of plastic (or _________).
Contractor shall furnish and install a (compatible) electric door release, and related power supply,
if required, depending upon master station(s) being used.
Contractor shall furnish and install the following OPTIONAL equipment where required, RY400
remote relay (for each 3 door openers), RY401 All-Call relay for up to 12 stations, RY402 In-use
adaptor for use with L.E.D. indicating remote(s).
Contractor shall observe all local and national electrical codes.
REQUIRED COMPONENTS:
|
S1
|
Screwdriver (for system installation/maintenance).
|
|
SM401
|
MASTER STATION. Maximum number per system depends on total system
configuration. Can be used to call only one (1) other master or remote station. White
ABS plastic finish. Requires IH400A desk/surface cabinet.
|
|
PK400
|
SYSTEM POWER SUPPLY. One (1) required per system to provide power for voice,
L.E.D. and tone signaling. Requires SS106 (24VAC) transformer.
|
|
SS106
|
16/24VAC PIGTAIL TRANSFORMER. Required to power PK400, and the optional
16VAC or 24VAC type door release only.
|
|
IR100B
|
INDOOR PLASTIC REMOTE. White color without any CALL button. Requires IH101
or IH102 (flush) or IH700W (surface) or IH400A Desk Cabinet/housing. Also requires the EC105 capacitor (to be field installed by installer).
|
| ------OR------ |
|
IR510B
|
INDOOR PLASTIC REMOTE. White color with built-in CALL button. Requires IH101
or IH102 (flush) or IH700W (surface) or IH400A Desk Cabinet/housing.
|
| ------OR------ |
|
IR141P
|
INDOOR PLASTIC REMOTE. White color with built-in CALL button and Privacy
switch. Requires IH101 or IH102 (flush) or IH700W (surface) or IH400A Desk
Cabinet/housing.
|
| ------OR------ |
|
IR143P
|
INDOOR PLASTIC REMOTE. White color with 3 built-in CALL buttons and Privacy
switch. Requires IH101 or IH102 (flush) or IH700W (surface) or IH400A Desk
Cabinet/housing.
|
| ------OR------ |
|
IR141U
|
INDOOR PLASTIC REMOTE. White color with built-in CALL button and In-Use
indicator. Requires IH101 or IH102 (flush) or IH700W (surface) or IH400A Desk
Cabinet/housing. Requires RY402 in-use adaptor.
|
| ------OR------ |
|
OR610W
|
PLASTIC REMOTE. White color. Surface mounts right on wall. With built-in CALL
button. No housing required.
|
| ------OR------ |
|
OR610
|
PLASTIC REMOTE. Brown color. Surface mounts right on wall. With built-in CALL
button. No housing required.
|
| ------OR------ |
|
OR642
|
PLASTIC REMOTE. Brown color. Surface mounts right on wall. With built-in
illuminated call button. No housing required. Maximum 1- OR642 (or OR642W per
system). Other remotes may be OR610/OR610W type.
|
| ------OR------ |
|
OR642W
|
PLASTIC REMOTE. White color. Surface mounts right on wall. With built-in
illuminated call button. No housing required. Maximum 1- OR642W (or OR642 per
system). Other remotes may be OR610/OR610W type.
|
| ------OR------ |
|
OR510
|
ALUMINUM REMOTE. With built-in plastic CALL button. Requires IH101 (flush) or
OH700 (surface) back box.
|
| ------OR------ |
|
OR502SS
|
STAINLESS STEEL REMOTE. With built-in metal CALL button. Requires IH101
(flush) or OH700 (surface) back box and EC105 non-polarized capacitor (installed in
the field).
|
| ------OR------ |
|
OR541U
|
ALUMINUM REMOTE. With built-in plastic CALL button and In-Use light. Requires
IH101 (flush) or OH700 (surface) back box. Requires RY402 in-use adaptor.
|
| ------OR------ |
|
--->>>
|
Contact our sales dept. for other remotes available.
|
OPTIONAL COMPONENTS:
|
RY401
|
ALL-CALL RELAY ADAPTOR. Use (1) per system for All-Call capability for up to 12
total stations.
|
|
RY402
|
IN-USE ADAPTOR. Use (1) per system is using any of the IR141U and/or OR541U
remotes with in-use indicator lights.
|
|
PK407A
|
SPECIALTY RELAY ADAPTOR. Used when connecting a door opener other than a
16VAC or 24VAC type to system. One (1) PK407A required for each building entry
door opener.
|
|
EC105
|
NON-POLARIZED CAPACITOR. Required when using the OR502SS or IR100B
remote stations, or remotes without a built-in capacitor.
|
BACK BOXES/HOUSINGS (Not Required for 'OR6' Remotes):
|
IH102
|
FLUSH MOUNTING RING. Use with IR510B or IR100B or IR141P or IR141U when flush
mounting into sheetrock or wood paneled wall. Galvanized Steel finish.
|
| ------OR------ |
|
IH101
|
FLUSH MOUNTING BOX. Use with IR510B or IR100B or IR141P or IR141U when flush
mounting onto wall studding. Galvanized Steel. Also used to flush mount 'OR5' series
outdoor remotes.
|
|
IH400A
|
DESK ADAPTOR. Use with SM401 for desk or surface mounting. Use with IR510B or
IR100B or IR141P or IR141U for desk mounting. White ABS plastic (supplied with
rubber feet).
|
|
IH700W
|
SURFACE MTG. BOX. Use with IR510B or IR100B or IR141P or IR141U indoor remote
for surface mounting. White enamel over steel.
|
|
OH700
|
SURFACE MOUNTING BOX. Use with 'OR5' series outdoor remotes. Black enamel
finish over Steel.
|
WIRING REQUIREMENTS:
From master to master (and to the PK400 control unit), run 6 common wires, and selective wire
for every master -AND- remote on the system. For example, if you have four (4) masters and one
(1) remote, you have five (5) TOTAL stations on the system. Add these five (5) wires to the six (6)
common wires, and you need a minimum of 11 common wires between the master stations. Add
2 common wires from master to master, if All-Call is desired. If background music is desired, add
1 additional common wire from master to master, and run a 2-conductor #18AWG shielded cable
from the background music source to the PK400 power supply unit (up to 100 feet maximum). If
door release is desired, add 1 common wire to master to master cable, and run a 2-conductor
#18AWG cable from each door opener to the PK400 control unit (up to 100 feet maximum).
If ALL-CALL is not used, limit length of cable as follows:
--------------------------------------------------------------------------------------------------------
Common Wire Gauge Size #22AWG - Maximum 500 feet (150 meters)
Common Wire Gauge Size #20AWG - Maximum 800 feet (240 meters)
Common Wire Gauge Size #18AWG - Maximum 1,200 feet (360 meters)
If ALL-CALL is used, limit length of cable as follows:
--------------------------------------------------------------------------------------------------------
Common Wire Gauge Size #22AWG - Maximum 250 feet (75 meters)
Common Wire Gauge Size #20AWG - Maximum 400 feet (120 meters)
Common Wire Gauge Size #18AWG - Maximum 600 feet (180 meters)
Master stations may be loop wired. NOTE: due to common impedance coupling, tone signals
may be amplified and heard by master stations monitoring other stations. With long wires, this
interference may be quite loud. This effect may be reduced by using two (2) conductors for the
terminal 'C' wire, or by using the next larger size conductor (#20AWG instead of #22AWG), or by
wiring the system in a star pattern, where all stations home run to the PK400 control unit.
For the OR642 or OR642W remote stations, run a 2-conductor twisted pair #22AWG cable from
each remote station, back to the PK400 control unit, up to 250 feet. For runs up to 1,000 feet,
use a 2-conductor (shielded) #18AWG cable. Only one (1) OR642 or OR642W remote may be
used per system.
For the IR143P remote stations, run a 4-conductor 2-twisted pair #22AWG cable from each
remote station, back to the PK400 control unit, up to 250 feet. For runs up to 1,000 feet, use a
2-conductor (shielded) #18AWG cable.
For the IR141U or OR541U remote stations, run a 2-conductor twisted pair #22AWG cable from
each remote station, back to the RY402 in-use adaptor, up to 250 feet. For runs up to 1,000 feet,
use a 2-conductor (shielded) #18AWG cable.
For all other remote stations, run a 2-conductor twisted pair #22AWG cable from each remote
station, back to the nearest master station only, up to 250 feet. For runs up to 1,000 feet, use a
2-conductor (shielded) #18AWG cable.
Run a 2-conductor #18AWG cable from the 24VAC transformer to the PK400 power supply, up to
50 feet. NOTE: the audio and door opener and transformer cables must be in separate jackets
and not in the same cable jacket.
See system wiring diagram IL603 for more complete wiring information.
|