FEATURES
Requires only 2-Wires for Intercom and Electronic Chime
Powers from 4- 'C' Batteries or Optional DC Power Supply
Built-in Electronic Chime
Built-in Momentary Electric Door Release Pushbutton
Modern Styling
Master can mount over existing Door Chime Station
Wide Variety of Weather-Resistant Remotes
SPECIFICATIONS/DIMENSIONS
| SM202: | Height: |
7.50" (191mm)
|
| | Width: |
5.13" (131mm)
|
| | Projects: |
1.63" (42mm) from surface of wall
|
| OR202: | Height: |
4.75" (121mm)
|
| | Width: |
3.50" (89mm)
|
| | Projects: |
1.25" (32mm) from surface of wall
|
ARCHITECTS' AND ENGINEERS' SPECIFICATIONS
The intercom system shall be Alpha Communications® Duo-Com series, or approved equal.
Master station (model SM202) shall be surface mount and shall include a built-in voice amplifier,
electronic chime signal and momentary electric door release pushbutton. Master shall be powered
by 4- 'C' batteries (or optional SS6C DC power supply adaptor). Master station shall have
intercom and chime volume controls and a Talk/Listen switch. The Listen circuit shall automatically
time-out after approximately 20 seconds. Outdoor remote station shall be the model
OR202, and shall surface mount right on the surface of the wall, or over a single gang electrical
'gem' box.
Contractor shall furnish and install a (compatible) electric door release, and related power supply,
if required.
Contractor shall observe all local and national electrical codes.
REQUIRED COMPONENTS:
|
SM202K
|
Duo-Com Kit. Each kit includes one (1) SM202 master station, one (1) OR202
remote station and 33 feet (10m) of connecting cable for the intercom functions.
Powers off of 4- 'C' batteries or optional SS6C DC power supply adaptor.
|
OPTIONAL COMPONENTS:
|
CP202SS
|
Stainless Steel Cover plate to protect the OR202 outdoor remote station. Mounts over
OR202 remote to provide protection against vandalism.
|
|
PK407A
|
SPECIALTY RELAY ADAPTOR. Used when connecting a door opener other than a
non-fail-safe type to system, such as a magnetic door opener.
|
|
SS6C
|
6VDC POWER SUPPLY ADAPTOR. Plugs into standard 120VAC outlet, and
provides low-voltage power for SM202 intercom functions.
|
|
?????
|
ELECTRIC DOOR OPENER. Must be low-voltage type. Powered by separate low-
voltage transformer or power supply (compatible with door opener being used).
|
WIRING REQUIREMENTS:
Run a 2-conductor twisted pair #22AWG cable from the SM202 master to the OR202 remote
station, up to 250 feet. For runs up to 1,000 feet, use a 2-conductor (shielded) #18AWG cable.
Run a 2-conductor #18AWG cable from the SS6VDC power supply (if used) to the SM202
master up to 50 feet. Run a 2-conductor #18AWG cable from the SM202 master to the optional
electric door opener, up to 50 feet. NOTE: the audio and door opener and transformer cables
must be in separate jackets and not in the same cable jacket. See system wiring diagram for
more complete wiring information.
|