Used in apartment houses and other multi- family dwellings to provide intrusion, fire, smoke, medical, or panic emergency alarm signal to main annunciator station.

The Alpha Communications®/Tektone SF202B Tek-Alert™ series apartment intruder alarm system is designed for intruder, panic and other alarm indications, in a multi-dwelling application. The model SF202B provides for connection of detection devices to signal intrusion through doors or windows, or to signal fire, smoke, medical, panic, or other emergency conditions.

The intruder alarm is armed by selecting either the IN or OUT mode, and pressing the middle button on the unit. As an aid to prevent false alarms, the unit cannot be armed unless the protected doors and windows are closed, and the Green L.E.D. is lighted. In the IN mode, the unit is ready for instant operation after approximately 40 seconds. In the OUT mode, a 40 second delay permits exiting. When returning, a 25 second delay allows the occupant time to disarm the unit, during which time a pre-alarm tone is heard as a reminder. The unit is diarmed by entering a private four-digit code on the push-button keypad. If the unit is not disarmed, a loud pulsating tone will be heard, and may be transmitted to external alarm signaling devices. The alarm will continue for five (5) minutes, unless disarmed, and then will stop. A flashing Red L.E.D. will continue to signal that an alarm has occurred.

The panic alarm is activated by pressing buttons 2/7 and 4/9 (marked 'ALARM') on the unit simultaneously, or by pressing any panic buttons that may be installed on the premises. A loud steady tone will be heard and will be transmitted to external devices, if connected. The panic alarm will continue until reset by entering the four-digit disarm code.

An output is provided to operate a remote annunciator station. An external relay (model #SF210) is available to operate external alarm devices. For complete security, battery backup should be provided to retain alarm status, and to provide alarm service during and after a power interruption.


SF202B Apt. Intruder Alarm

SF202B
FEATURES
• Private 4-Digit Security Code (set at each apartment station)
• 3 Detection Loops (Door, Window, Emergency/Smoke/Panic)
• IN/OUT Switch for Instant or Time-Delayed Operation
• Low-Voltage Operation (16VAC or 12VDC)
• Surface Mounts over Standard Single Gang Electrical 'Gem' Box
• Pre-Alarm Tone Signal
• 2 Alarm Tones (Steady and Interrupted)
• Instant Panic Alarm (24-hour operation)
• 100% Solid State Electronics
• Cannot Be Armed with Door or Window Open
• 5-Minute Alarm Cut-off Timer for Intrusion Alarm

SPECIFICATIONS

DIMENSIONS
SF202B: Height: 7.00" (178mm) Width: 5.00" (127mm) Projects: 1.38" (36mm) from surface of wall
ARCHITECTS' AND ENGINEERS' SPECIFICATIONS The apartment intruder alarm system shall be Alpha Communications®/Tektone SF202B Tek-Alert™ series, or approved equal. At each of the remote apartment locations, contractor shall furnish and install the model SF202B intruder alarm station. SF202B shall contain IN/OUT selector slide switch, Red (ON) and Green (READY) L.E.D. indicators, five (5) button alarm keypad, built-in tone alarm speaker and 4-digit alarm code configuration capability. Unit shall be made of high-impact ABS plastic in an off White color. Unit shall mount over standard single gang electrical 'gem' box, or single gang plaster ring.

At the main security location, contractor shall furnish and install one (1) model DS100/xxx (xxx=number of lamp indicators-must be in multiples of 4) annunciator console with appropriate backbox (specify flush, surface or desk mounting). Annunciator shall have indicator lights no less than 5/8" by 5/8" in size, to allow for positive alarm recognition, when activated. Unit shall have model ST005D test button(s) to allow for testing of all indicator lamps, as often as desired. Annunciator shall be latching type, and indicator lights will remain lighted until reset at the master and at the SF202B intruder station.

Contractor shall furnish and install all necessary transformers, control units, remote contact devices, smoke detectors, heat detectors, panic buttons, etc. as required for proper system operation. Contractor shall observe all local and national electrical codes.

NOTE: The SF202B system is not an approved fire alarm system, and use of it to indicate a fire or smoke condition is strictly voluntary, and at the discretion and risk of the user.

REQUIRED COMPONENTS S1 Scrulox Screw Driver. Required for annunciator installation and maintenance. N553A Lamp Extraction Tool. One (1) recommended for each master annunciator station. It allows easy extraction of any annunciator bulb (#LI014) that may have burned out. SF202B Apartment Intruder Alarm Station. One (1) required for each apartment or remote location that has to be alarmed/monitored. Mounts on standard single gang electrical 'gem' box, or single gang plaster ring. Comes with plug-in wiring harness connector. DS100 Master Control module with tone speaker, tone-off light and tone-off button. One (1) required at each master station location. Requires one or more PM201/4 4-lamp addon modules and annunciator frame/housing. Can handle up to 5- PM201/4 modules. AM100 Blank module. Used when more than 5- PM201/4 lamp modules are needed. Each AM100 module can handle up to 9- PM201/4 lamp modules. ST005D Test Button. Required on each DS100 and/or each AM100 module that has any of the PM201/4 lamp modules.
PM201/4 4-Lamp Modules. One (1) required for each master station, for each four (4) or less indicating locations required. Up to five (5) PM201/4's can be installed onto a DS100 module and up to nine (9) PM201/4's can be installed onto an AM100 module. Each module that has any PM201/4 lamps should have the ST005D test button. RP021CM Lens Caps and Custom Markings. Four (4) are required for each PM201/4 module. ST201I Key Switch. One (1) required for each DS100 annunciator for resetting of alarm lamp switches at master annunciator. Installs into DS100 or AM100 module, and takes the same space (height) as a row of PM201/4 lights. PK2019 Controller Unit. One (1) required for each master annunciator station. Requires SS106 transformer for power.
SS106 16/24VAC Transformer. One (1) required to power each PK2019 control unit. SS250 16VAC Power Transformer. One (1) required to power each 100 (or less) SF202B intruder alarm stations.
OF200 Series Annunciator Frame. One (1) required for each master station. Use with OH200 series flush housing --OR-- OH300 series surface back box --OR-- IH300 series desk cabinet. Multiple frames and housings may be used for larger master stations. OH200 Series Flush Housing. One (1) required for each master station. Use with OF200 series master annunciator frame, for flush mounting. ------OR------
OH300 Series Surface Back Box. One (1) required for each master station. Use with OF200 series master annunciator frame, for surface mounting. ------OR------
IH300 Series Desk Cabinet. One (1) required for each master station. Use with OF200 series master annunciator frame, for desk top mounting. ------AND------
Open and/or Closed Contact Switches (provided by the customer), for each remote location.

OPTIONAL COMPONENTS IR019B Remote Indicator. One (1) required if you need to have a remote tone signal sound at a location, other than the master(s), when an alarm signal has activated. Mounts over two (2) gang electrical back box. Stainless steel faceplate with Tone-Off button. SF210 Alarm Expander Unit. Used with individual SF202B units (non multi-dwelling) to allow connection to remote sounder and/or battery backup devices. Requires separate SS106 transformer and BA001 12VDC gel cell battery. BA001 12VDC Gel Cell Battery. Required for use with SF210 alarm expander.

WIRING REQUIREMENTS: See system wiring diagram no. AWD040 for more complete wiring information.