Nurse/Emergency-Call Components

The SF153N emergency push stations are used with the NC110N, NC150N and the NC200N series nurse-call systems. They have a built-in Call-Placed L.E.D.

The Alpha Communications®/Tektone SF153N emergency push station is used to initiate a system 'Emergency' signal. It may be used independently or connected with other call stations and/or intercom stations. It is used primarly with the NC110N, NC150N, NC150R or NC200Nseries nurse-call systems. Calling the nurse is accomplished by depressing the push-button switch located at the center of the station to the 'IN' position. This call cannot be canceled except at the point of origin. Depressing the push-button again to the 'OUT' position cancels the call. The station includes a lighted 'CALL-PLACED' L.E.D. indicator. The SF153N station features a rugged stainless steel faceplate, with the word 'EMERGENCY' permanently stamped into the faceplate.


SF153N Emergency Push Station

SF153N
FEATURES


• U.L. 1069 Listed - 4th Edition Standards
• Simple Push-button Calling
• Lighted CALL-PLACED L.E.D. Indicator
• Rugged Stainless Steel Faceplate
SPECIFICATIONS


Dimensions:
Height: 4.50" (114mm)
Width: 2.75" (69mm)
Depth: 2.06" (53mm)
Projects: 0.50" (13mm) from mounting surface
Connections: Positive screw terminal connections, mounted on a P.C. board. Mounting: Mounts over standard 1-gang electrical back box with plaster ring (model IH358 with model IH357).

ARCHITECTS' AND ENGINEERS' SPECIFICATIONS

The emergency push stations shall be Alpha Communications®/Tektone SF153N, or approved equal and shall include a lighted 'CALL-PLACED' L.E.D. indicator. A call will be registered at the annunciator panel(s), corridor light(s) and any optional corridor zone lights. The station's 'CALL- PLACED' LED will light if the call switch is pushed. All electronic components needed for these features and functions shall be mounted on a printed circuit board and all station components shall be mounted on a rugged stainless steel faceplate. The station shall be mounted into a standard single gang electrical box (or ring). Positive screw terminals shall be provided for connections. The SF153N shall be U.L. listed 1069 to the latest standards. Contractor shall observe all local electrical codes.

WIRING REQUIREMENTS:

See appropriate system wiring diagram for more complete wiring information.