The PK124 is used with our nurse-call and emergency-call systems, as well as many of our other intercom systems, to provide emergency back-up battery power.

The Alpha Communications®/Tektone PK124 battery charger is used primarily with our nurse-call and emergency-call systems, as well as other intercom systems to provide battery back-up power to these systems. The PK124 is used in conjunction with two (2) of our model BA001 12VDC batteries, and provides for continuous battery charging, in the event of a power failure. Standby operating power is provided for up to six (6) hours. NOTE: TIME MAY VARY DEPENDING UPON SYSTEM SIZE, TYPE, and NUMBER OF DEVICES BEING POWERED. The PK124 operates on 24VAC (30VA) low-voltage Class II wiring, using our model #SS106 transformer. All PK124 connections are positive screw terminal type. NOTE: The installer must provide a 4 Amp Fuse in series with the BA001 battery connections (as per wiring diagram).


PK124 Annunciator Control Unit

PK124
FEATURES


• Easily Installs Right on Finished Wall Surface or in Optional Junction Box
• Operates on Safe Low-Voltage Class II Wiring

• Positive Screw Terminal Connections

• Reliable Alternate Power Supply

SPECIFICATIONS


Dimensions: Height: 9.50" (241mm) Width: 2.38" (61mm) Depth: 2.25" (58mm) from mounting surface

Construction: Rugged Extruded Aluminum Case Connections: Positive screw terminal connections.

ARCHITECTS' AND ENGINEERS' SPECIFICATIONS The battery charger unit shall be Alpha Communications®/Tektone model PK124, or approved equal, and shall provide continuous battery charging of the model BA001 batteries. Unit shall provide back-up (emergency) power to the intercom (or other) system, in the event of a power failure. Low voltage wiring shall be used and positive screw terminals shall be provided for installation wiring. The PK124 shall be mountable right to the surface of the wall or in the optional model IH151N U.L.® Listed junction box cabinet. Contractor shall observe all local electrical codes.

REQUIRED COMPONENTS SS106 16/24VAC PIGTAIL TRANSFORMER. One (1) required to power each PK124. BA001 12VDC GELL CELL BATTERY. One (1) or two (2) required for each PK124, depending upon the system in which they are being used. See system wiring diagram for qty. of BA001 batteries needed, for your specific system. Requires a customer supplied 4-Amp fuse to be installed inline.

OPTIONAL COMPONENTS IH151N U.L.® Listed steel junction box cabinet, in a painted Beige finish. Used to house and protect the PK124 and its wiring connections.

WIRING REQUIREMENTS See individual system wiring diagram for more complete wiring information.