Installs with Scrulox type tamper-resistant mounting screws (provided)
SPECIFICATIONS
|
Dimensions:
| Height: |
6.88" (175mm)
|
| | Width: |
5.00" (127mm)
|
| | Depth: |
1.50" (38mm) (When Flush Mounted)
|
| | Projects: |
0.50" (13mm) from mounting surface
|
| Construction: |
Solid Extruded Aluminum faceplate.
|
| Speaker/Mic: |
2.50" (64mm) mylar speaker with voice frequency response, Model SK024.
|
| Mounting: |
Mounts flush to wall using IH101 flush back box or IH102 flush mounting ring.
Can be surface mounted using OH700 surface back box (Steel painted Black).
|
ARCHITECTS' AND ENGINEERS' SPECIFICATIONS
Remote station(s) shall be Alpha Communications®/Tektone model OR101 or approved equal.
Station faceplate shall be solid extruded aluminum in a natural anodized finish. The speaker/
microphone shall be a 2.50" (64mm) mylar cone, high-sensitivity type with excellent voice-frequency
response, and shall be protected by a Black ABS plastic speaker grille. Pigtails
shall be provided for wiring terminations.
REQUIRED COMPONENTS:
|
S1
|
Screwdriver (for system installation/maintenance).
|
|
IH101
|
Flush Steel Back Box
|
| ----OR---- |
|
IH102
|
Flush Steel Mounting Ring
|
| ----OR---- |
|
IH102
|
Flush Steel Mounting Ring
|
| ----OR---- |
|
OH700
|
Surface Back Box (Steel painted Black)
|
OPTIONAL COMPONENTS:
EC105 NON-POLARIZED CAPACITOR. Required when using the OR101 remotes with the
SM201B, SM203B, SM205/SM210 series or SM400 series master stations, for a 2-wire
configuration.
WIRING REQUIREMENTS:
The OR101 remotes are only a 2-wire type. See individual system wiring diagram for more
complete wiring information.