Dimensions:
Height: 2.375" (60mm)
Width: 4.25" (108mm)
Depth: 4.75" (120mm) from mounting surface
Volume Control: Adjustable potentiometer built-in.
Connections: Screw Terminal Connectors.
ARCHITECTS' AND ENGINEERS' SPECIFICATIONS
The power supply/amplifier shall be Alpha Communications®/S.T.R.
model NH208TVU, or approved equal. Amplifier shall operate from a 16VAC
(30VA) U.L. Listed transformer (SS106 or SS146). All wiring to power
supply/amplifier shall be low-voltage Class II wiring, installed as per all
federal, state, and local electrical codes. Power supply/amplifier shall
surface mount right to the finished wall and shall be installed in a
suitable environment that is free from excessive dirt, dust, temperature,
humidity, grease and water. Power supply/amplifier shall provide the
intercom amplification and signaling power for proper system operation.
For most secure installation, power supply should be installed into a
lockable equipment cabinet/housing. Power supply/amplifier shall be
installed a safe distance from any source of electrical interference.
OPTIONAL COMPONENTS:
DO-001 (or equivalent) 16VAC Door Release.
TU1007A Multi Entrance Audio Adaptor. Used when switching audio
(intercom) and door release between two (2) or more entrance
stations. Used in addition to system amplifier. Use one (1) for
(2) entrances, use two (2) for (3-4) entrances, use three (3)
for (5-6) entrances and use four (4) for (7-8) entrances.
No additional transformer needed.
R2006 Alphatone Adaptor. Required to be field installed into
each HT2006 handset that will be called from any door station(s).
Used in NH208TVU type systems only.
PK407A Specialty Relay Adaptor. Used when connecting a door opener
other than a 16VAC type to system. One (1) required for each
building entry door opener.
------OR------
Used when an individual HT2006 selective call button is needed
to trigger another signaling application other than an electric
buzzer signal.
One (1) required for each signaling application (per HT2006 button).
DV4 4-Zone Paging Adaptor. Used in addition to all other system
components, when paging from one or more handsets is required.
Has 10W of audio output split between 1-4 zones. Output of DV4
can be sent into one or more public address amplifiers for larger
paging requirements. Each DV4 requires its own SS146 (40VA)
transformer.
WIRING REQUIREMENTS:
Wiring between handsets shall be 4-common #22AWG and 1 selective wire #22AWG,
for each handset station connected on the system. For example, a system with
8- HT2006/10 handsets would require 4-common and 8-selective wires for a total of
12 wires (minimum). Then add 1-#22AWG wire for each handset pushbutton that will
activate an electric door release, add 1-#22AWG wire for each pushbutton
(at any entry door) that will selectively signal to one or more handsets connected
to that pushbutton. In the illustration shown above for 8- HT2006/10 handsets,
if you had an 8-button front entry panel and a door release you would add 1 door
opener wire, and 8 selective call button wires, for an additional 9 wires added to
the original 12, for a minimum wiring requirement of 21 wires. Add one more
#22AWG wire for each of the other HT2006 pushbuttons will be used for any
other signaling purposes, such as paging, etc. See the individual system wiring
diagram AWD057 for more complete wiring information.
|