Nurse-Call/Emergency-Call Masters

Fully Microprocessor-Based Audio-Visual Nurse-Call System. Supervised loop wiring. U.L. 1069 Listed. Can interface to printer or pocket-page system. Code Blue capababilites.

The Alpha Communications®/Tektone NC300 series Tek-Micro-Care™ microprocessor-based audio-visual nurse-call system provides all of the most desirable ergonomic features and functions required by today's health care administrative professionals. The NC300 addresses the needs of both patient and nurse by combining ease of operation, accurate two-way voice communication, and an English language format prominently displayed on a high-resolution, compact CRT. The NC300 system also includes masters that incorporate SPILL-PROOF membrane switches mounted on an attractive housing. The keys are colored and grouped accordingly for ease of operation, and the handset is an integral part of the master station. The heart of the system is the Central Processing Unit (CPU). CPU's are available with or without dual system networking and serial data ports. Each CPU supports four (4) primary CRT/masters and four (4) secondary CRT/masters. Total NC300 system capacity is up to 512 addressable points. All master stations have the ability to select specific areas and/or rooms, set patient priority level and room status, or change and reassign any station within the system. Selection or reassignment of paging zones, choosing from selected areas, or All-Call is equally simplified by user-friendly, menu-driven programming procedures. Many of the more commonly used functions are easily selectable by depressing the appropriate keys on the SPILL-PROOF membrane switch. Masters also include ALPHA-character selection for ALPHA-NUMERIC room programming and calling. All programming on any master, or any portion of each menu may be protected by user-selectable passwords, to prevent tampering or unauthorized changes. Coupling all of these features and functions with the installed cost benefit provided by multiplexed wiring and plug-in terminations means you have chosen the most efficient and cost-effective nurse-call system on the market.


NC300 Series Nurse-Call System

NC303 with NC313 Monitor
FEATURES


• U.L. 1069 Listed, 4th Edition Standards
• English Language Format
• 8 Paging Zones and All-Call
• Programmable Alpha-Numerical Room Numbering
• Programmable Bed Status
• Master-to-Master Communications
• Supervised Multiplexed Wiring
• 32 Levels of Priority
• Staff Locator and Follower
• 4 Simultaneous Talk Paths (with 4 Masters)
• Master with SPILL-PROOF Membrane Switches
ARCHITECTS' AND ENGINEERS'
SPECIFICATIONS


The audio-visual microprocessor nurse-call system shall be Alpha Communications®/Tektone NC300 series, or approved equal. At each of the bed locations, contractor shall furnish and install a model IR301B or IR311B (single) or IR302B or IR312B (dual) bedside station and the required SF301/8 call-cords (or other specialty type cords as required). At each bath location, contractor shall furnish and install a model SF340B (push/pullcord) or SF337C (water resistant) emergency-call station. At each remote location, contractor shall furnish and install a model LI380 (or model LI384A) corridor dome light. Where required, contractor shall furnish and install the necessary LI386B corridor zone light(s), model IR310C staff stations, model IR315E remote duty stations, and model IR300B multi-purpose stations.

At each of the main nurse's location, contractor shall furnish and install one (1) model NC303 master station, along with its associated NC313 VGA monitor (and NC314A converter). At the central location, contractor shall furnish and install one of the following CPE control units: Model NC350C/64 (64 station/2 master capacity-no serial output) ------OR------ Model NC350C/64P (64 station/2 master capacity-(1) serial output) ------OR------ Model NC350C128P (128 station/4 master capacity-(1) serial output) ------OR------ Model NC350CPX2 (256 station/4 master capacity-(2) serial outpus)

Contractor shall furnish and install the model PC-25 uninterruptable power supply (for each CPU) where required.

System shall be U.L. listed 1069 to the latest standards. Contractor shall observe all local electrical codes.


WIRING REQUIREMENTS:

See system wiring diagram no. IL421 for more complete wiring information.