Standard (non-supervised) 4-bulb corridor dome light. Primarily used with the NC300 series microprocessor nurse-call system. White, Red, Green, Yellow color lenses.

The Alpha Communications® LI380 sectional corridor lamp provides visual indication of calls originating from patient, staff, duty, bath, emergency, presence, and code call stations. Patient priority and staff presence are indicated by RED, GREEN, YELLOW, and WHITE colored sections. When used with any room station or IR310B Staff Station, the LI380 will indicate all calls originated from that room. When used with the IR300B Multi-Purpose Station or the IR315B Duty Station, the LI380 may be used as a zone light to indicate all calls from the zones to which those stations are assigned.


LI380 4-Bulb Corridor Dome Light

LI380



FEATURES


• UL 1069 Listed - 4th Edition Standards
• Easy bulb replacement - no tools required
• Snap-in colored lens sections
• Excellent visibility
• Interchangeable lenses

SPECIFICATIONS

Dimensions:		Height:	4.56" (115mm overall)		
			Width: 	4.56" (115mm)
			Depth: 	3.00" (75mm) from finished wall surface
Bulb(s):		#1829 28v. 70mA (model LI028A)
Power Requirement:	24VDC, 51mA (per bulb)
Finish 		
Base:			FOG WHITE flame retardant ABS plastic
Lens:			Flame retardant translucent polycarbonate plastic
				 (YELLOW, RED, GREEN and WHITE)
Mounting: 	    	Standard double gang plaster ring or Alpha Communications® 
			model IH356 box with model IH355 mounting ring.

ARCHITECTS' AND ENGINEERS' SPECIFICATIONS

Corridor dome lamp shall be Alpha Communications®/Tektone model LI380 or approved equal. The corridor lamp shall be sectional in design. Lamps shall include a WHITE, RED, YELLOW, and GREEN flame retardant polycarbonate translucent plastic lens. All lenses shall be mounted on a FOG-WHITE flame retardant polystyrene translucent plastic base panel. The lenses shall be individually removable without the use of tools for ease of bulb replacement. The four bulbs in conjunction with the different colored lenses shall provide for indication of patient call priority and staff presence.

LI380 shall be U.L. 1069 listed to the latest 4th Edition standards.

Contractor shall observe all local and national electrical codes.

WIRING REQUIREMENTS:

See the specific system wiring diagram for more complete wiring information.


Navigation Bar

Copyright© 1996-2007 Alpha Communications®. All Rights Reserved.
42 Central Drive, Farmingdale, NY 11735-1202

Web-site Designed and Maintained by Alpha Media Inc.