All-call standard between indoor remote stations
SPECIFICATIONS
| Dimensions: | Height: |
7.00" (178mm)
|
| | Width: |
5.00" (127mm)
|
| | Depth: |
1.50" (38mm) (When Flush Mounted)
|
| | Projects: |
0.50" (13mm) from mounting surface
|
| Construction: |
High-Impact ABS plastic faceplate (White).
|
| Speaker/Mic: |
3.50" (89mm) paper cone speaker with voice/music response, Model SK013.
|
| Mounting: |
Mounts flush to wall using IH101 flush back box or IH102 flush mounting ring.
Can be surface mounted using IH700W surface back box (painted White).
Can be desk mounted using IH400A White plastic Desk Cabinet.
|
ARCHITECTS' AND ENGINEERS' SPECIFICATIONS
Remote intercom/music station(s) shall be Alpha Communications®/Tektone model IR704BD or
approved equal. Station faceplate shall be high-impact ABS plastic in a White finish. Four (4)
push-button switches shall be provided for Inside Call, Monitoring, Door Answering and Electric
Door Release functions. The Monitor button shall be of the locking type. A three-position slide
type volume control switch shall be provided. The speaker/microphone shall be a 3.50" (89mm)
paper cone, high-sensitivity type with excellent voice/music frequency response. Screw terminals
shall be provided for wiring terminations.
REQUIRED COMPONENTS:
|
S1
|
Screwdriver (for system installation/maintenance).
|
|
IR704BD
|
Inside remote station(s). Up to 18 total may be used per system.
|
|
PK724
|
Tek-Com system amplifier. One (1) required per system, or the 'EK' series AM/FM
music/intercom master station. Each PK724 or 'EK' master requires the SS102A or
SS105B 16VAC transformer.
|
|
DO-001
|
16VAC Electric Door opener (or equivalent 16VAC door opener).
|
| -----OR----- |
|
IH101
|
Flush Steel Back Box
|
| -----OR----- |
|
IH102
|
Flush Steel Mounting Ring
|
| -----OR----- |
|
IH700W
|
Surface Back Box (painted White)
|
| -----OR----- |
|
IH400A
|
White Plastic Desk Cabinet
|
OPTIONAL COMPONENTS:
DOOR REMOTE STATION(S): Maximum (2) per system. Voice operation will be parallel type
operation. Choose from the following types of outdoor remotes: OR601, OR601W, OR603,
OR603W, OR604A, OR604AW, OR101, OR501B or OR502SS. See catalog section on indoor and
outdoor remotes for more information on these remote stations.
WIRING REQUIREMENTS:
Run a 2-twisted pair #22AWG cable from IR704BD to IR704BD, and then back to the PK724
amplifier (or 'EK' series master station). If there is one(1) IR704BD on a run you may run up to
600 feet (180m). If there are two (2) IR704BD stations on a run, you may run up to 300 feet
(90m). If there are three (3) IR704BD stations on a run, you may run up to 160 feet (50m). If there
are four (4) IR704BD stations on a run, you may run up to 80 feet (25m). Each system can have
no more than four (4) intercom wire runs. If there are more than 10 stations installed on the
system, only 10 may be turned **fully** on at one time.
Run a 2-conductor #18AWG cable from IR704BD to IR704BD, and then back to the PK724 amplifier
(or 'EK' music master), for the door release function. Run a 2-conductor #18AWG cable from
the 16VAC door opener, back to the PK724 amplifier (or 'EK' music master).
Run a two (2) conductor #22AWG from each door station without any call buttons, back to the
PK724 amplifier (or 'EK' music master). Run a three (3) conductor #22AWG from each door
station with a non-lighted call button, back to the PK724 amplifier (or 'EK' music master). Run a
four (4) conductor #22AWG from each door station with a lighted call button, back to the PK724
amplifier (or 'EK' music master). See individual system wiring diagram for more complete wiring
information.