FEATURES
Simple push button operation
Easy installation
Advanced design
Automatic privacy
Clear voice quality
Can be flush, surface or desk mounted
Attractive White station with English and Universal Graphic Symbols
SPECIFICATIONS
| Dimensions: |
Height: | 7.00" (178mm) |
| |
Width: | 5.00" (127mm) |
| |
Depth: | 1.50" (38mm) (When Flush Mounted) |
| |
Projects: | 0.50" (13mm) from mounting surface |
| Construction: | High-Impact ABS plastic faceplate (White). |
| Controls | Individually replaceable push-buttons with self-wiping plated contacts. Identified
(with English word and Universal graphic symbol) for TALK, LISTEN and DOOR functions. |
| Speaker/Mic: | 3.50" (89mm) paper cone speaker with voice response, Model SK013. |
| Mounting: | Mounts flush to wall using IH101 flush back box or IH102 flush mounting ring.
Can be surface mounted using IH700W surface back box (painted White).
Can be desk mounted using IH400A White plastic Desk Cabinet. |
ARCHITECTS' AND ENGINEERS' SPECIFICATIONS
Apartment stations shall be Alpha Communications®/Tektone model IR104C or approved equal,
equipped with momentary action push-buttons for TALK, LISTEN, and DOOR operation. Each
push-button hall have both English and Universal Graphic Symbol imprinting. The speaker/
microphone shall be a 3.5" high-sensitivity type with voice-frequency response. Screw terminal
connections shall be provided for positive wiring termination. The station shall be molded of
high-impact, flame retardant ABS plastic, in a fog white finish. Stations shall be (flush or surface
or desk) mounted using the appropriate back box or housing.
REQUIRED COMPONENTS:
IH101 Flush Steel Back Box
--OR--
IH102 Flush Steel Mounting Ring
--OR--
IH700W Surface Back Box-Steel-Painted White
--OR--
IH400A White ABS Plastic Desk Cabinet
PK543 Amplifier (1 per system)
DO-001 (or equivalent) Door Release
SS102A or SS105B 16VAC Transformer (for PK543)
Lobby Entry Panel (1 per building entry)
S1 Screwdriver (for installation/maintenance)
OPTIONAL COMPONENTS:
| PK502B |
Multi-Entrance Relay Adaptor (use 1 for each additional entry panel after
1st panel--maximum of 8 entrances). No additional transformer needed.
|
| PK407A |
Specialty Relay Adaptor. Used when connecting a door opener other than a 16VAC
type to system. One (1) required for each building entry door opener.
|
WIRING REQUIREMENTS:
Apartment riser wiring shall be 3-common #22AWG and 1 selective wire #22AWG, for each
station connected to the riser cable. Add 1-#22AWG common wire if 2nd tone signal will be used
with optional apartment pushbuttons, to signal apartments when visitor is at apartment door. See
wiring diagram no. IL487 for more complete wiring information.
|