Nurse-Call/Emergency-Call Masters

Ideal for Senior Citizen Residence and any other Emergency-Call type application. The CM800 masters can be flush, surface or desk mounted with the proper housing.

The Alpha Communications®/Tektone® CM800 Tek-Care™ series emergency-call system is designed for multi-family dwellings housing the elderly or handicapped, or for other emergency-call/panic type applications.

Any tenant requiring emergency assistance can signal the building manager, security guard and/or neighbors by activating a conveniently located pullcord (or push-button) switch in each apartment or remote signaling location.

Depending upon the system option(s) selected, the activation of the pull cord switch can activate the master (CM800) annunciator, apartment dome lights, floor bell(s) and individual apartment electric door opener(s).

The CM800 master annunciator is modular and can be flush, surface or desk mounted, and is available in any size, in multiples of four (4) lights. The CM800 features built-in tone signal, and tone silence button and light. Model ST005D 'TEST' buttons are optional, but strongly recommended for lamp testing each module.


CM800 Series Emergency-Call System

CM800 Series
FEATURES
  • Modular (CM800) Master Station available for any size application (in multiples of 4 lights)
  • Built-in Electronic Tone Signal and Tone Silence Switch
  • Wide Variety of Remote Pullcords/Push-button Stations
  • Form 'C' Dry Contact Relay output to power remote devices
  • Ideal for Elderly Housing and Emergency-Call Applications

    ARCHITECTS' AND ENGINEERS' SPECIFICATIONS
    The emergency-call system shall be Alpha Communications®/Tektone® Tek-Care™ CM800 series, or approved equal. In each of the apartments, contractor shall furnish and install two (2) model SF117/2B emergency pullcord stations. (Note: use model SF117/2B with basic system and one (1) option. Use model SF117/4B if system uses two (2) or more options. If call-placed indicator light is required, substitute the SF118/2B or SF118/4B for the SF117/2B or SF117/4B units).

    At the manager's office/apt., contractor shall furnish and install one (1) model CM800/xxx (xxx=number of lamp indicators-must be in multiples of 4) annunciator console with appropriate backbox (specify flush, surface or desk mounting). Annunciator shall have indicator lights no less than 5/8" by 5/8" in size, to allow for positive alarm recognition, when activated. Unit shall have model ST005D test button(s) to allow for testing of all indicator lamps, as often as desired. Annunciator shall be non-latching type, and indicator lights will remain lighted only as long as emergency-call station is activated. Resetting of annunciator may only be accomplished by resetting the emergency-call station to the OFF position, and not at the annunciator.

    ADD FOR OPTION A: At each apt. entrance door, contractor shall furnish and install one (1) model LI381 corridor lamp assembly.

    ADD FOR OPTION B: In each hallway, contractor shall furnish and install one (1) (or more- specify) model BE005 surface mount vibrating bell(s).

    ADD FOR OPTION C: At each apt. entrance door, contractor shall furnish and install one (1) continuous-duty electric door opener (type to be determined by type of door and lock supplied by the door supplier).

    Contractor shall furnish and install all necessary power supplies and transformer(s) for proper system operation. CM800 annunciator shall be installed with Scrulox type tamper-resistant mounting screws. Contractor shall furnish to building manager, a model S1 screwdriver and model N553A lamp bulb extractor tool for system maintenance. All wiring shall be as per the system manufacturer.

    REQUIRED COMPONENTS:
    S1 Scrulox Screw Driver. Required for annunciator installation and maintenance.
    N553A Lamp Extraction Tool. One (1) recommended for each master annunciator station. It allows easy extraction of any annunciator bulb (#LI014) that may have burned out.
    CM800 Master Control module with tone speaker, tone-off light and tone-off button. One (1) required at each master station location. Has no indicator lamps or TEST button.
    -----OR Choose from one of the following CM800 modules with lamp indicators-----
    CM800/04 Same as CM800 with 4 indicator lamps and ST005D 'TEST' button.
    CM800/08 Same as CM800 with 8 indicator lamps and ST005D 'TEST' button.
    CM800/12 Same as CM800 with 12 indicator lamps and ST005D 'TEST' button.
    CM800/16 Same as CM800 with 16 indicator lamps and ST005D 'TEST' button.
    CM800/20 Same as CM800 with 20 indicator lamps and ST005D 'TEST' button.
    AM100 Blank module-no components. Usually used for future expansion of master station(s).
    AM800/24 Same as AM100 with 24 indicator lamps and ST005D 'TEST' button.
    AM800/32 Same as AM100 with 32 indicator lamps and ST005D 'TEST' button.
    AM800/36 Same as AM100 with 36 indicator lamps and ST005D 'TEST' button.
    ST005D Test Button. Included on each CM800/xx and/or each AM800/xx module that has any of the lamp indicator modules.
    RP021CM Lens Caps and Custom Markings. One (1) is required for each lamp indicator on each master station.
    PK2019 Controller Unit. One (1) required for each master annunciator station. Requires SS106 transformer for power.
    SS106 16/24VAC Transformer. One (1) required for any of the following items being used on a system: PK2019, PK601A, and individual BE005 floor bell.
    OF200 Series Annunciator Frame. One (1) required for each master station. Use with OH200 series flush housing --OR-- OH300 series surface back box --OR-- IH300 series desk cabinet. Multiple frames and housings may be used for larger master stations.
    OH200 Series Flush Housing. One (1) required for each master station. Use with OF200 series master annunciator frame, for flush mounting.
    ------OR------
    OH300 Series Surface Back Box. One (1) required for each master station. Use with OF200 series master annunciator frame, for surface mounting.
    ------OR------
    IH300 Series Desk Cabinet. One (1) required for each master station. Use with OF200 series master annunciator frame, for desk top mounting.
    SF117/2B 2-Pole Emergency Pull Station. One (1) or more required for each apartment, or remote signaling location. Can activate up to (2) system functions. No call placed light. Mounts on single gang electrical 'gem' box. White plastic finish with 6 foot cord.
    ------OR------
    SF117/4B 4-Pole Emergency Pull Station. One (1) or more required for each apartment, or remote signaling location. Can activate up to (4) system functions. No call placed light. Mounts on single gang electrical 'gem' box. White plastic finish with 6 foot cord.
    ------OR------
    SF118/2B 2-Pole Emergency Pull Station. One (1) or more required for each apartment, or remote signaling location. Can activate up to (2) system functions. With call placed light. Mounts on single gang electrical 'gem' box. White plastic finish with 6 foot cord.
    ------OR------
    SF118/4B 4-Pole Emergency Pull Station. One (1) or more required for each apartment, or remote signaling location. Can activate up to (4) system functions. With call placed light. Mounts on single gang electrical 'gem' box. White plastic finish with 6 foot cord.
    ------OR------
    SF117/3 4-Pole Emergency Pull Station. One (1) or more required for each apartment, or remote signaling location. Can activate up to (4) system functions. No call placed light. Mounts on single gang electrical 'gem' box. Stainless steel finish with 6 foot cord. NOTE: must use this type of signaling station when any customer-supplied smoke detectors are used. Contact us for details on this system option!!
    ------OR------
    SF154B Emergency Push Station. One (1) or more required for each apartment, or remote signaling location. Can activate up to (2) system functions. No call place light, but has a mechanical color change indicator, when button is depressed. Mounts on single gang electrical 'gem' box. White plastic faceplate with locking plastic switch.

    OPTIONAL COMPONENTS:
    LI381 Emergency Dome Light. One (1) required for each apartment, or remote signaling that requires a hallway light indicator. White ABS plastic with white bulb cover. Mounts over two (2) gang electrical back box. Includes 24 volt white bulb.
    IR019B Remote Indicator. One (1) required if you need to have a remote tone signal sound at a location, other than the master(s), when an alarm signal has activated. Mounts over two (2) gang electrical back box. Stainless steel faceplate with Tone-Off button.
    BE005 24VAC Floor Bell. One (1) required per floor, if you need to have a loud floor signal sound when any pull-cord or push station has been activated on that floor. When any BE005 floor bells are used you must add an additional 24VAC transformer, to be used for the floor bells only. Contact us for details on specific type needed for your system.
    ?????? Electric Door Opener. One (1) required per apartment/suite door if you need to have the door automatically un-lock, when a device has been activated in that apartment. Please contact us to assist you in selecting the right type of door opener for your door type and lock mechanism.

    WIRING REQUIREMENTS:
    See system wiring diagram no. IL514 for more complete wiring information.