Misc. Specialty Products and Tools

Used in Elevator and other Emergency intercom applications. The AND16 has 16 indicator lights, is fully supervised, and can be flush or surface mounted to wall.

The Alpha Communications®/Ring AND16 series elevator emergency annunciator is designed to be used with the RM5000 or CB910 series Ring intercom systems, for applications requiring audible/visual annunciation from calling locations. Specifically designed for use as an elevator communications system, the AND16 has other applications in such areas as nursing homes, retirement homes, security and door status systems. For greater security, the system automatically and constantly supervises the cables for opens, shorts, blown fuses and power interruption. L.E.D. indicators instantly identify these problems.

The AND16 must be used in conjunction with the RM5000 or CB910 central control units, and the remote alarm circuits, model #AN912. An interom master station will be required for any voice communication. An AN912 may annunciate on a maximum of two (2) AND16 display locations. The AND16 displays may be ganged together for larger system configurations.


AND16 Elevator Emergency Annunciator

AND16
FEATURES
• Brushed Stainless Steel Faceplate
• 16 Alarm Indicating Lights
• Fully Supervised Wiring
• Can Be Ganged Together for Larger Requirements
• Flush or Surface Mounts with Appropriate Back Box
• One or Two AND16 Locations May be Used on Each System


SPECIFICATIONS
DIMENSIONS

Height: 9.90" (251mm) Width: 5.50" (140mm) Depth: 1.60" (40mm) when flush mounted

Maximum power consumption with 16 indicators lighted: 370mA

ARCHITECTS' AND ENGINEERS' SPECIFICATIONS The elevator emergency annunciator shall be Alpha Communications®/Ring AND16 series, or approved equal. Unit shall be finished in a brushed stainless steel finish, and shall have 16 lamp indicators. Unit shall be fully supervised and shall L.E.D. indicators for Power, Call, Shorts, Fuse, and Opens. Unit shall be used in conjunction with the RM5000 (or CB910) series intercom system and central control unit.

Contractor shall furnish and install all necessary power supplies, control units, etc. as required for proper system operation. Contractor shall observe all local and national electrical codes.

REQUIRED COMPONENTS AND16 16 Light Emergency Annunciator. One (1) or two (2) used per system location. Must be used with a model AN912 remote alarm circuit (per remote intercom location) and either the RM5000 or CB910 series intercom system, with all related components. Use model BBF863 Flush or model BBS863 Surface Back Box. AN912 Remote Alarm Circuit. One (1) required for each remote intercom station or device. BBF863 Flush Back Box. One (1) required for each AND16 annunciator that needs to be flush mounted.
------OR------
BBS863 Surface Back Box. One (1) required for each AND16 annunciator that needs to be surface mounted.
------AND------
The required RM5000 or CB910 series intercom system components required.

WIRING REQUIREMENTS See AND16 system wiring diagram for more complete wiring information.