FEATURES
40-Station Master to Master Systems Capacity
Up to Four (4) Simultaneous Private Talk Paths
Optional PA Paging and Door Speaker Capability
Optional Electric Door Release at Door Station
Simple 8 or 10 Conductor Loop Wiring
Masters can be Surface or Desk Mounted
Wide Variety of Weather-Resistant Remotes
SPECIFICATIONS
| 851/001 | Height: |
8.75" (222mm) NOTE: When surface wall mounted.
|
| | Width: |
5.00" (127mm)
|
| | Depth: |
3.25" (83mm)
|
| 856/800 | Height: |
5.00" (127mm) NOTE: When surface wall mounted.
|
| | Width: |
3.75" (95mm)
|
| | Depth: |
3.00" (76mm)
|
| 857/800 | Height: |
9.75" (248mm) NOTE: When surface wall mounted.
|
| | Width: |
7.50" (191mm)
|
| | Depth: |
3.50" (89mm)
|
| 2900/001 | Height: |
7.40" (187mm)
|
| | Width: |
3.95" (101mm)
|
| | Depth: |
.50" (23mm) from surface of finished wall
2.00" (52mm) when flush mounted
|
| 2970/001 | Height: |
8.00" (204mm)
|
| | Width: |
4.50" (115mm)
|
| | Depth: |
2.75" (70mm) when surface mounted
|
ARCHITECTS' AND ENGINEERS' SPECIFICATIONS
The intercom system shall be Alpha Communications®/Elvox 851/001 series, or approved
equal. Master stations shall be model 851/001 and shall be surface mount (or desk mount) and
shall include call buttons numbered 1-10 and lettered A-D, a door release push button and a
paging button. System shall be powered directly by the 120VAC wall outlet, using model
856/800 power supply (for master to master intercom only) or model 857/800 paging power
supply (if any paging or door speaker options are used). Outdoor remote stations shall be the
model 2900/001 (flush) or model 2970/001 (surface) type (with 930/000 speaker/microphone installed).
Contractor shall observe all local and national electrical codes.
REQUIRED COMPONENTS:
|
851/001
|
MASTER STATION-40 CALL. Up to 40 per system. Beige/Brown ABS plastic
finish. Mounts directly on surface of finished wall. Can be desk mounted with
optional model 2/805 desk adaptor.
|
|
856/800
|
SYSTEM POWER SUPPLY. One (1) required for systems with master to master
communication only. If the PA paging, or door speaker or electric door release
options are used, you must use the model 857/800 power supply instead of the
model 856/800 power supply. Operates on 120VAC.
|
| ------OR------ |
|
857/800
|
SYSTEM PAGING POWER SUPPLY. One (1) required for systems if any of the PA
paging, or door speaker or electric door release options are used. Operates on
120VAC.
|
OPTIONAL COMPONENTS:
|
2900/001
|
OUTDOOR REMOTE. Nat. Aluminum finish. Flush mounts into wall. With built-in
CALL button. Comes with flush back box included. Requires model 930/000
speaker/microphone (which is field installed by the contractor).
|
| ------OR------ |
|
2970/001
|
OUTDOOR REMOTE. Nat. Aluminum finish. Surface mounts onto wall. With built-in
CALL button. Comes with surface housing included. Requires model 930/000
speaker/microphone (which is field installed by the contractor).
|
| ------OR------ |
| Contact our sales dept. for other remotes available. |
|
930/000
|
SPEAKER/MICROPHONE. Installs into either the 2900/001 or 2970/001 door
station. This unit is field installed by the contractor.
|
| NOTE: When PA paging is utilized on system, you must add the appropriate paging
speakers, and the required (separate) PA amplifier. Contact our sales dept. for more
information on this option. |
WIRING REQUIREMENTS:
From master to master, run an 8-conductor #22AWG cable (non shielded/non twisted), up to
1,500 feet, when using the 856/800 power supply. If using the 857/800 paging power supply,
add 2-conductors #22AWG to above wiring, for a total of 10-conductor #22AWG between the
master stations. See system wiring diagram for more complete wiring information, and for
connections to optional equipment such as PA paging, door speaker and/or electric door
release.
|